Doepfer A-198 Trautonium / Ribbon Controller User Manual

Browse online or download User Manual for Audio Doepfer A-198 Trautonium / Ribbon Controller. Doepfer A-198 Trautonium / Ribbon Controller User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
doepfer
System A - 100
Trautonium / Ribbon Controller
A-198
1
1. Introduction
Module A-198 is a so-called Trautonium resp. Rib-
bon Controller. It provides variable Control Voltages
and Gate signals generated by combined
position /
pressure sensor. The controlling element of the A-
198 is a linear position sensor (length about 50 cm)
that has available a pressure sensor too.
Touching the sensor with a finger generates a Con-
trol Voltage
that is
proportional to the position of
the finger. The Scale - i.e. the relation between
position difference and voltage difference - is ad-
justable
with a potentiometer at the front panel. A
Hold switch is used to determine if the CV voltage is
held after removing the finger or if the voltage jumps to
0V. In the last case (Hold = off) a
Gate
signal is
derived from the CV voltage whenever a finger tou-
ches the sensor (e.g. for triggering an Envelope Gene-
rator / ADSR).
A pressure sensor made of conductive rubber arran-
ged below the position sensor generates a
second
Control Voltage that increases with higher pressure
of the finger. Even for this CV the Scale is adjustable.
A
second Gate
signal is triggered as soon as the
pressure exceeds a certain value. The Gate Thres-
hold is adjustable at the front panel.
A-198
Trautonium / Ribbon Ctr.
Scale
CV
Gate
Position
Scale
CV
Gate
Pressure
Control
Board
Off
On
Hold
Thres
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - 1. Introduction

doepferSystem A - 100Trautonium / Ribbon Controller A-19811. IntroductionModule A-198 is a so-called Trautonium resp. Rib-bon Controller. It pr

Page 2 - 2. Overview

A-198 Trautonium / Ribbon ControllerSystem A - 100doepfer106. Patch-SheetThe following diagrams of the module can help yourecall your own Patches.

Page 3 - 3. Controls

A-198 Trautonium / Ribbon ControllerSystem A - 100doepfer22. OverviewControls:1 Scale : Scale / spread control for Position Con-trol Voltage outpu

Page 4

doepferSystem A - 100Trautonium / Ribbon Controller A-19833. Controls1 ScaleThe position sensor of the A-198 is in principle alinear potentiometer

Page 5 - 4. In- / Outputs

A-198 Trautonium / Ribbon ControllerSystem A - 100doepfer4the Trautonium the sound disappears immediately ifthe finger is removed (no release).3 LED

Page 6 - 5. User Examples

doepferSystem A - 100Trautonium / Ribbon Controller A-19854. In- / Outputs! CVThe position dependent Control Voltage CVPOS isavailable at this out

Page 7 - Ribbon Sensor

A-198 Trautonium / Ribbon ControllerSystem A - 100doepfer65. User ExamplesIn the first place module A-198 and the accessoryposition/pressure sensor

Page 8

doepferSystem A - 100Trautonium / Ribbon Controller A-1987Fig. 3: “Sound of a hand passing over a wineglass”P By means of the CV-to-MIDI Interface

Page 9

A-198 Trautonium / Ribbon ControllerSystem A - 100doepfer8Fig. 4: A-198 as a "keyboard"The patch of fig. 4 shows the application of the A

Page 10 - A-198 TRC

doepferSystem A - 100Trautonium / Ribbon Controller A-1989determines if all semitones or only tones of the minor/major scale or notes of a chord are

Comments to this Manuals

No comments